• About
    • Our Team
    • Location
    • Industry Case Studies
    • Mission & Values
    • Corporate Responsibility
    • Vendor Management
    • History
    • Contact
  • Industries
    • Agribusiness
    • Food & Beverage
    • Metals & Steel
    • Mining, Aggregate, & Concrete
    • Oil & Gas
    • Paper
    • Power Generation & Energy
    • Water & Wastewater
    • Wind Services
  • Products
    • Type
    • Manufacturers
    • Asset Management Program
  • Generators
  • Remanufacture
    • Electrical Repairs
    • Mechanical Repairs
    • Machining
  • Field Services
    • All Services
    • Installation and Commissioning
    • Overhead Crane & Hoist Services
    • Wireless Equipment Condition Monitoring IoT
    • Predictive & Preventative
      • Vibration Analysis
      • On-Site Electrical Testing
      • Large AC and DC Motor PM and Repair
      • Gear Reducers
      • Precision Laser Alignment
  • Asset Management
    • Asset Management Program
    • Transport & Logistics
  • Careers
  • Login

Decatur Industrial Electric

Contact Us

Service & Quotes: 217-428-6621

You are here: Home / 2014 / Archives for December 2014

Archives for December 2014

Action List for Rotor Anomalies

Your reliability analyst just told you that they suspect a rotor cage anomaly on one of your critical motors. What can you do to lower the risk of a catastrophic failure, reduce the chance for secondary damage to the stator windings, and possibly extend production as long as possible?

The following list is a good start to accomplishing each of those lofty goals in the event of a rotor cage defect: 

  • Increase the testing frequency for trend analysis
  • Limit the starts and stops of the motor
  • Minimize load fluctuations of the motor
  • Determine the rotor design as open or closed bar
  • Determine the speed of the motor 

The most stress felt by the rotor cage is during the motor start-up. Once the motor is up and running the slip is very low and the stress on the rotor bars is greatly reduced. Minimizing load fluctuations focuses on the same subject as limiting start-ups in that load fluctuations will create varying current and stress on the rotor. If you can base load the motor with the rotor anomaly and rely on other motors to vary with load demand you would reduce the stress on the fault. Knowing the rotor design is important to understand the risk of the situation. If the rotor is a closed bar design then the rotor bars are mostly underneath the rotor iron and even if the bar is cracked or broken the overlapping iron will prevent the rotor bar from exiting the slot. This lowers your overall risk and allows you to delay any immediate action for the sake of production. However, if the rotor is an open bar design then as the rotor defect advances it is very common for the rotor bar slot to open up allowing a broken bar to escape and come in contact with the stator iron and windings. This is often catastrophic and at minimum a 2-3 times multiplier in the cost of repairs. Finally, know the speed of your motor. A two-pole motor running near 3600rpm has significantly more centrifugal force on the rotor bars than a four or six-pole motor. The combination of a two-pole motor with an open bar design places the motor at a high risk and may force your hand to take immediate action.
 
Decatur Industrial Electric has a crew of reliability tech’s who have the latest technology to test rotors in-plant and in the shop floor. We can help by partnering with your reliability team! 

 

 

Filed Under: Uncategorized

Archives

  • June 2025
  • May 2025
  • April 2025
  • March 2025
  • February 2025
  • January 2025
  • November 2024
  • August 2024
  • June 2024
  • May 2024
  • April 2024
  • March 2024
  • January 2024
  • November 2023
  • October 2023
  • September 2023
  • August 2023
  • June 2023
  • May 2023
  • April 2023
  • February 2023
  • January 2023
  • December 2022
  • November 2022
  • October 2022
  • August 2022
  • July 2022
  • June 2022
  • May 2022
  • April 2022
  • March 2022
  • February 2022
  • January 2022
  • December 2021
  • November 2021
  • October 2021
  • September 2021
  • August 2021
  • July 2021
  • June 2021
  • April 2021
  • March 2021
  • February 2021
  • January 2021
  • December 2020
  • November 2020
  • October 2020
  • September 2020
  • August 2020
  • July 2020
  • June 2020
  • May 2020
  • April 2020
  • March 2020
  • February 2020
  • January 2020
  • December 2019
  • November 2019
  • October 2019
  • September 2019
  • August 2019
  • July 2019
  • June 2019
  • May 2019
  • April 2019
  • March 2019
  • February 2019
  • January 2019
  • December 2018
  • November 2018
  • October 2018
  • September 2018
  • August 2018
  • July 2018
  • June 2018
  • May 2018
  • April 2018
  • March 2018
  • February 2018
  • January 2018
  • December 2017
  • November 2017
  • October 2017
  • September 2017
  • August 2017
  • July 2017
  • May 2017
  • April 2017
  • March 2017
  • February 2017
  • January 2017
  • December 2016
  • November 2016
  • October 2016
  • September 2016
  • August 2016
  • July 2016
  • June 2016
  • May 2016
  • April 2016
  • March 2016
  • January 2016
  • December 2014
  • November 2014

Copyright © 2025 Decatur Industrial Electric - 217-428-6621